• Single Phase Compact Oil Immersed Power Distribution Transformer
Single Phase Compact Oil Immersed Power Distribution Transformer
discuss personally
Model
D-11/160
D-11/125
D-11/80
Basic info
Brand ROCKWILL
Model NO. Single Phase Compact Oil Immersed Power Distribution Transformer
Rated voltage 11kV
Rated frequency 50/60Hz
Rated capacity 160kVA
Series D
Product Detail

Product Overview

Rockwill's Single Phase Distribution Transformers combine proven engineering with innovative design to deliver unmatched reliability for residential, commercial and industrial applications. Our transformers feature optimized construction and premium materials to ensure superior performance in diverse operating conditions.

Key Features & Benefits

  • Optimized Thermal Design: 15% better cooling efficiency than conventional models

  • Short-Circuit Reinforced: Withstands 25x rated current for 2 seconds

  • Low Noise Operation: <45dB for urban installations

  • Eco-Friendly Options: Biodegradable ester oil available

  • Smart Monitoring Ready:Optional IoT connectivity for predictive maintenance

Technical Specifications

  • Capacity Range: 10kVA to 333kVA

  • Primary Voltage: Up to 34.5kV

  • Standards Compliance: IEEE C.57, IEC 60076, ANSI/CSA

  • Temperature Range: -25&deg;C to +40&deg;C (standard) / Custom designs available

Product Parameters

Reliable Engineering Design

  • Advanced Spiral Coil Designwith longitudinal oil channels for enhanced heat dissipation

  • Reinforced Coil Support Systemfor superior short-circuit current resistance

  • Patented Lifting Structureensures safe transportation and installation

  • Rigorous Quality Controlwith multiple structural improvements based on decades of field experience

Premium Material Selection

  • Oxygen-Free Copper Windingswith special surface treatment for reduced load loss

  • High-Grade Silicon Steel Coreswith ultra-low unit loss for minimized no-load consumption

  • Industrial-Grade Laminated Wood Insulationmaintains structural integrity under short-circuit conditions

  • Deep-Filtered Transformer Oilwith minimal moisture/gas content for stable operation

  • Aging-Resistant Sealsprevent leaks throughout the service life

  • ISO 9000 Certified Materialsfrom rigorously audited suppliers

Application Scenarios

  • Urban Power Distribution: Compact designs for space-constrained installations

  • Rural Electrification: Robust construction for harsh environments

  • Commercial Complexes: Low-noise operation for sensitive areas

  • Industrial Parks: High overload capacity for variable loads

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!